Upload Siemens S7-200 Program using PPI cable

Dear PLC Technical members, 

Welcome to our followers on the Blog PLC Technical, today in this article I will introduce you how to upload Siemens S7-200 Program using the PPI cable point to point interface. I can only now explain this application to you.

UPLOAD S7-200 SIEMENS PROGRAM USING PPI

I. Upload Siemens S7-200 Program using PPI cable


In this part, I will guide you how to upload Siemens S7-200 Program using PPI cable, even though the S7-200 is an old PLC, I wanted to share this article because it still needs revision and fault tracking.



But first I will also explain to you several CPU modules for the S7-200, and let us take a look at USB ,MPI,DP,Point to point adapter cable for Siemens S7-200, NetWork Adapter for S7 System.

1. USB adapter cable for Siemens S7-200


USB Adapter Siemens S7-200 PLC programming cable, five meters with communication indicator, direct use the Step7 software, USB adapter, for upload Siemens S7-200 program at the level the PLC Siemens.

Features: 
  • Support the Siemens S7-200-300-400 PLC communications
  • Support PPI-MPI-DP communications
  • Install drive, without generating serial, directly select USB

the siemens PPI câble



2. CPU modules

CPU221:
  • 6 digital inputs
  • 4 digital outputs
  • Not expandable with modules
  • Siemens article number: 6ES7211-0BA22-0XB0
CPU222:
  • 8 digital inputs
  • 6 digital outputs
  • Up to 2 expansion modules
  • Siemens article number: 6ES7212-1AB22-0XB0
CPU224:
  • 14 digital inputs
  • 10 digital outputs
  • Max. 7 expansion modules
  • Siemens article number: 6ES7214-1BD22-0XB0
CPU224XP:
  • 14 digital inputs
  • 10 digital outputs
  • 2 analog inputs
  • 1 analog output
  • Up to 7 expansion modules
  • Siemens article number: 6ES7214-2AD23-0XB0
CPU226:
  • 24 digital inputs
  • 16 digital outpus
  • Maximum 7 expansion modules
  • Siemens article number: 6ES7216-2BD22-0XB0

Control Cabinet PLC S7-200


CPU 224 SIMATIC S7-200
CPU 224 SIMATIC S7-200


3. HOW TO UPLOAD S7-200 PROGRAM FROM CPU 224 TO PC


  1. Create a new project
  2. Communication: interface parameter assignments used select PC/PPI cable. PPI
  3. Should be USB if you are connecting with a PPI to PC
  4. The Read button reads PLC and selects it from the drop down list for upload
  5. Upload program from CPU 224 to PC: Press upload the PC will read the PLC
  6. The Program uploads successfully

Have a gander at this article to see the software used STEP7-Micro/WIN for uploading the program SIMATIC S7-200 CPU 224.using the Siemens PPI câble.


Starting STEP 7-Micro/WIN Open the Micro/win STEP7 programming, click " settings PG/PC interfaces " fasten and choose " PC/PPI cable (PPI)" After you click on the " Properties " button, appeared in the accompanying figure:


PC adapter PPI

Set the neighborhood sequential number in the interface and mark off the" modem association: USB or COM.


Properties PC/PPI


Checking the communication Parameters for Micro/WIN:

  • Check that the location of the PC/PPI link in the Interchanges discourse box is set to 0.
  • Check that the interface for the arrange parameter is set for PC/PPI cable(COM4).
  • Check that the transmission rate is set to 9.6 kbps

communication Parameters for Micro/WIN


  • Double tap the " connection ", the accompanying figure:

CPU 224 REL

Upload Siemens S7-200 Program
At the point when you transfer a project to your PC utilizing Micro/WIN, the S7-200 transfers the program and memory.

To transfer your Project from a S7-200 CPU: 
  • Select the File > Upload menu order. 
  • Snap the Upload Button.

Upload Siemens S7-200 Program

  • The program is being uploaded to the PC

program S7-200 is being uploaded to the PC


  • The Program uploads successfully

Program S7-200 uploads successfully





From here we have finished the subject of the upload Siemens S7-200 Program using PPI cable from PLC to PC, if you like it, please share it with friends until it benefits, and then meet on a new topic on blog PLC Technical. 
Regards,
PLC Technical

Post a Comment

Post a Comment (0)